na2701::> storage shelf show -connectivity Shelf Name: 1.SHJHU2027000151 Stack ID: 1 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:51:99:82 Serial Number: SHJHU2027000151 Module Type: IOM12 Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Paths: Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN ------------------ --------- -------------------------- -------------------------- ------------------ ------ na2701-02 0a - - - - na2701-01 0a - - - - Errors: ------ Duplicate shelf IDs are not allowed in the same stack. Shelf Name: 2.SHFHU2031000076 Stack ID: 2 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:52:53:76 Serial Number: SHFHU2031000076 Module Type: IOM12E Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Paths: Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN Press to page down, for next line, or 'q' to quit... q na2701::> controller controller controller-replacement na2701::> rows 0 na2701::> storage shelf show -connectivity Shelf Name: 1.SHJHU2027000151 Stack ID: 1 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:51:99:82 Serial Number: SHJHU2027000151 Module Type: IOM12 Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Paths: Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN ------------------ --------- -------------------------- -------------------------- ------------------ ------ na2701-02 0a - - - - na2701-01 0a - - - - Errors: ------ Duplicate shelf IDs are not allowed in the same stack. Shelf Name: 2.SHFHU2031000076 Stack ID: 2 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:52:53:76 Serial Number: SHFHU2031000076 Module Type: IOM12E Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Paths: Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN ------------------ --------- -------------------------- -------------------------- ------------------ ------ na2701-02 0b - - - - na2701-01 0b - - - - Errors: ------ Duplicate shelf IDs are not allowed in the same stack. 2 entries were displayed. na2701::> storage shelf show -port Shelf Name: 1.SHJHU2027000151 Stack ID: 1 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:51:99:82 Serial Number: SHJHU2027000151 Module Type: IOM12 Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal SAS Ports: -- Port Speeds Gb/s -- Power Port Phy # IOM Port Type WWPN Operational Negotiated Status Status ----- --- --------- ----------------- ----------- ---------- ------ ----------- 0 A Host - 12.0 - - Enabled 1 A Host - 12.0 - - Enabled 2 A Host - 12.0 - - Enabled 3 A Host - 12.0 - - Enabled 4 A Host - - - - Empty 5 A Host - - - - Empty 6 A Host - - - - Empty 7 A Host - - - - Empty 8 A Host - - - - Empty 9 A Host - - - - Empty 10 A Host - - - - Empty 11 A Host - - - - Empty 12 A Host - - - - Empty 13 A Host - - - - Empty 14 A Host - - - - Empty 15 A Host - - - - Empty 16 A Disk - 12.0 - - Enabled 17 A Disk - 12.0 - - Enabled 18 A Disk - 12.0 - - Enabled 19 A Disk - 12.0 - - Enabled 20 A Disk - 12.0 - - Enabled 21 A Disk - 12.0 - - Enabled 22 A Disk - 12.0 - - Enabled 23 A Disk - 12.0 - - Enabled 24 A Disk - 12.0 - - Enabled 25 A Disk - 12.0 - - Enabled 26 A Disk - 12.0 - - Enabled 27 A Disk - 12.0 - - Enabled 0 B Host 500a09800e33c130 12.0 - - Enabled 1 B Host 500a09800e33c130 12.0 - - Enabled 2 B Host 500a09800e33c130 12.0 - - Enabled 3 B Host 500a09800e33c130 12.0 - - Enabled 4 B Host - - - - Empty 5 B Host - - - - Empty 6 B Host - - - - Empty 7 B Host - - - - Empty 8 B Host - - - - Empty 9 B Host - - - - Empty 10 B Host - - - - Empty 11 B Host - - - - Empty 12 B Host - - - - Empty 13 B Host - - - - Empty 14 B Host - - - - Empty 15 B Host - - - - Empty 16 B Disk 5000c500ca5e0d82 12.0 12.0 - Enabled 17 B Disk 5000c500ca5db5e6 12.0 12.0 - Enabled 18 B Disk 5000c500ca5dbf2a 12.0 12.0 - Enabled 19 B Disk 5000c500ca5dc0c6 12.0 12.0 - Enabled 20 B Disk 5000c500ca5db492 12.0 12.0 - Enabled 21 B Disk 5000c500ca5e0b16 12.0 12.0 - Enabled 22 B Disk 5000c500ca5e0792 12.0 12.0 - Enabled 23 B Disk 5000c500ca5e215a 12.0 12.0 - Enabled 24 B Disk 5000c500ca4c5fae 12.0 12.0 - Enabled 25 B Disk 5000c500ca4c8cca 12.0 12.0 - Enabled 26 B Disk 5000c500ca4c7f72 12.0 12.0 - Enabled 27 B Disk 5000c500ca4c7806 12.0 12.0 - Enabled FC Ports: Port ID Port Type Status --- --------- ----------- - - - PCIe Ports: -- Speed (Gb/s) -- Mod ID Type Bay Negotiated Maximum Status --- --- -------- --- ---------- ------- ------------------ - - - - - - - Errors: ------ Duplicate shelf IDs are not allowed in the same stack. Shelf Name: 2.SHFHU2031000076 Stack ID: 2 Shelf ID: 0 Shelf UID: 50:0a:09:80:08:52:53:76 Serial Number: SHFHU2031000076 Module Type: IOM12E Model: DS212-12 Shelf Vendor: NETAPP Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal SAS Ports: -- Port Speeds Gb/s -- Power Port Phy # IOM Port Type WWPN Operational Negotiated Status Status ----- --- --------- ----------------- ----------- ---------- ------ ----------- 0 A Host 500a09800e33c134 12.0 - - Enabled 1 A Host 500a09800e33c134 12.0 - - Enabled 2 A Host 500a09800e33c134 12.0 - - Enabled 3 A Host 500a09800e33c134 12.0 - - Enabled 4 A Host - - - - Empty 5 A Host - - - - Empty 6 A Host - - - - Empty 7 A Host - - - - Empty 8 A Disk 5000c500ca707465 12.0 12.0 - Enabled 9 A Disk 5000c500ca707ae1 12.0 12.0 - Enabled 10 A Disk 5000c500ca639245 12.0 12.0 - Enabled 11 A Disk 5000c500ca68b77d 12.0 12.0 - Enabled 12 A Disk 5000c500ca707351 12.0 12.0 - Enabled 13 A Disk 5000c500ca647215 12.0 12.0 - Enabled 14 A Disk 5000c500ca68b57d 12.0 12.0 - Enabled 15 A Disk 5000c500ca62dfed 12.0 12.0 - Enabled 16 A Disk 5000cca3b72e947d 12.0 12.0 - Enabled 17 A Disk 5000c500ca64b805 12.0 12.0 - Enabled 18 A Disk 5000c500ca6ffa79 12.0 12.0 - Enabled 19 A Disk 5000c500ca642f79 12.0 12.0 - Enabled 0 B Host - 12.0 - - Enabled 1 B Host - 12.0 - - Enabled 2 B Host - 12.0 - - Enabled 3 B Host - 12.0 - - Enabled 4 B Host - - - - Empty 5 B Host - - - - Empty 6 B Host - - - - Empty 7 B Host - - - - Empty 8 B Disk - 12.0 - - Enabled 9 B Disk - 12.0 - - Enabled 10 B Disk - 12.0 - - Enabled 11 B Disk - 12.0 - - Enabled 12 B Disk - 12.0 - - Enabled 13 B Disk - 12.0 - - Enabled 14 B Disk - 12.0 - - Enabled 15 B Disk - 12.0 - - Enabled 16 B Disk - 12.0 - - Enabled 17 B Disk - 12.0 - - Enabled 18 B Disk - 12.0 - - Enabled 19 B Disk - 12.0 - - Enabled FC Ports: Port ID Port Type Status --- --------- ----------- - - - PCIe Ports: -- Speed (Gb/s) -- Mod ID Type Bay Negotiated Maximum Status --- --- -------- --- ---------- ------- ------------------ - - - - - - - Errors: ------ Duplicate shelf IDs are not allowed in the same stack. 2 entries were displayed. na2701::> storage port show Speed Node Port Type Mode (Gb/s) State Status ------------------ ---- ----- ------- ------ -------- --------------- na2701-01 0a SAS - 12 enabled online 0b SAS - 12 enabled online na2701-02 0a SAS - 12 enabled online 0b SAS - 12 enabled online 4 entries were displayed. na2701::> No power commands available for this target Type the hot key to suspend the connection: Z na2701::> storage port show -instance Node: na2701-01 Port: 0a Port Type: SAS Description: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C) Firmware Revision: 03.08.09.00 Base WWN: 50:0a:09:80:0e:34:14:b0 Is Dedicated: true Is Redundant: false In Use: true Connector Type: mini-sas-hd Connector Vendor: Molex Inc. Connector Part Number: 112-00436+A0 Connector Serial Number: 008730980 Cable Length: 0.5m Cable End Identifier: end_0 Cable Identifier: 500a09800e3414b0-500a09800851abe9 Port Speed: 12 Gb/s Port State: enabled Port Status: online Phy State: [0] enabled, online, 12 Gb/s [1] enabled, online, 12 Gb/s [2] enabled, online, 12 Gb/s [3] enabled, online, 12 Gb/s Node: na2701-01 Port: 0b Port Type: SAS Description: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C) Firmware Revision: 03.08.09.00 Base WWN: 50:0a:09:80:0e:34:14:b4 Is Dedicated: true Is Redundant: false In Use: true Cable End Identifier: end_1 Cable Identifier: 500a09800e3414b4-500a09800e3414bf Port Speed: 12 Gb/s Port State: enabled Port Status: online Phy State: [0] enabled, online, 12 Gb/s [1] enabled, online, 12 Gb/s [2] enabled, online, 12 Gb/s [3] enabled, online, 12 Gb/s Node: na2701-02 Port: 0a Port Type: SAS Description: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C) Firmware Revision: 03.08.09.00 Base WWN: 50:0a:09:80:0e:33:c1:30 Is Dedicated: true Is Redundant: false In Use: true Connector Type: mini-sas-hd Connector Vendor: Molex Inc. Connector Part Number: 112-00436+A0 Connector Serial Number: 008731059 Cable Length: 0.5m Cable End Identifier: end_1 Cable Identifier: 500a09800e33c130-500a09800851a875 Port Speed: 12 Gb/s Port State: enabled Port Status: online Phy State: [0] enabled, online, 12 Gb/s [1] enabled, online, 12 Gb/s [2] enabled, online, 12 Gb/s [3] enabled, online, 12 Gb/s Node: na2701-02 Port: 0b Port Type: SAS Description: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C) Firmware Revision: 03.08.09.00 Base WWN: 50:0a:09:80:0e:33:c1:34 Is Dedicated: true Is Redundant: false In Use: true Cable End Identifier: end_1 Cable Identifier: 500a09800e33c134-500a09800e33c13f Port Speed: 12 Gb/s Port State: enabled Port Status: online Phy State: [0] enabled, online, 12 Gb/s [1] enabled, online, 12 Gb/s [2] enabled, online, 12 Gb/s [3] enabled, online, 12 Gb/s 4 entries were displayed. na2701::> na2701::>